7.1 Plug in the power adapter to the operator, the other end should
be plugged into an electrical outlet. Red LED should be on
indicating power is plugged in.
7.2 Press and hold the “Door Setting” button (red color button) for 10
seconds, buzzer will start to beep one at a time, then a continu-
ous beep. Release the button when the buzzer emits a long
continuous beep.
7.3 The door operator will try to open the door all the way until it hits
the door stopper, then it will close all the way until it is fully
closed. During this travel limit setup procedure, do not interrupt
the door by blocking it. Otherwise, it will affect the normal
operation.
INSTALLATION - IN SWING
NOTE
Before proceeding to the following steps, ensure you have cleared the
path so the door can be open and closed without hitting any obstacle.
Door Setting
Button (red)
8. Mounting the electromagnetic lock (For Model DM-100 only)
(If electric strike is used, please omit this section. )
8.1 The electromagnetic lock is energized when the door is fully closed to provide additional security and privacy.
The h olding force of the electromagnetic lock is approx. 100lb (45kg). For in-swing right door, the electromagnetic lock
should be mounted on the upper right corner of the door. For in-swing left door, the electromagnetic lock should
be mounted on the upper left corner of the door. Diagram below shows the location and configuration after the
lock has been installed. Note: Do not mount the armature plate on the corner of 2 door jambs, it should be
mounted on the top door jamb.
TODORO TM
TO
DOR
O
TM
Note: In-Swing right
door installation
shown.
Note: In-Swing left
door installation
shown.
7. Program the OPEN and CLOSE travel limits
The door opener will automatically detect the open and close travel limited. It is capable to detect the fully open and
fully closed positions. Follow the procedures below to set the travel limits.
25
INSTALLATION - OUT SWING
If the wire is too long, you may use a
cable tie or tape to secure the wire on
the door.
Terminal T1